{"id":608694,"date":"2024-06-07T09:48:23","date_gmt":"2024-06-07T13:48:23","guid":{"rendered":"https:\/\/platohealth.ai\/mdcg-guidance-on-safety-reporting-in-ivd-performance-studies-specific-aspects-eu\/"},"modified":"2024-06-08T06:13:39","modified_gmt":"2024-06-08T10:13:39","slug":"mdcg-guidance-on-safety-reporting-in-ivd-performance-studies-specific-aspects-eu","status":"publish","type":"post","link":"https:\/\/platohealth.ai\/mdcg-guidance-on-safety-reporting-in-ivd-performance-studies-specific-aspects-eu\/","title":{"rendered":"MDCG Guidance on Safety Reporting in IVD Performance Studies: Specific Aspects | EU","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"
\n
\n
\n
\n
\n
\n
\n
\n

The new article describes in detail specific aspects related to the reporting requirements associated with performance studies involving in vitro diagnostic medical devices.<\/span><\/p>\n<\/div><\/div>\n

\n\t\t\t<\/div>\n

<\/p>\n

\n
\n

\t\t\t\t\"MDCG<\/span>\n\t\t\t<\/div>\n<\/p><\/div>\n

<\/p><\/div>\n

<\/p>\n

\n
\n
\n
\n

<\/span>Table of content<\/span><\/h2>\n<\/div><\/div>\n

<\/p>\n

\n
\n

The Medical Device Coordination Group (MDCG), an EU advisory body in the sphere of medical devices, has published a guidance document dedicated to safety reporting in performance studies of in vitro diagnostic (IVD) medical devices under Regulation (EU) 2017\/746 (IVDR). <\/span><\/p>\n

The document provides an overview of the applicable regulatory requirements, as well as additional clarifications and recommendations to be taken into consideration by medical device manufacturers, study sponsors, and other parties involved in order to ensure compliance thereto. <\/span><\/p>\n

It is also important to mention that provisions of the guidance and recommendations provided therein could be subject to changes, should such changes be reasonably necessary to reflect corresponding amendments to the underlying legislation.<\/span><\/p>\n<\/div><\/div>\n

\n\t\t\t<\/div>\n

<\/p><\/div>\n

<\/p>\n

\n
\n
\n
\n

<\/span>Responsibilities for Reporting<\/span><\/h2>\n

Under the general rule, reportable events must be reported by the sponsor of the post-market surveillance (PS), which may be the manufacturer, the legal representative, or another designated entity. This responsibility ensures accountability and compliance with regulatory requirements.<\/span><\/p>\n

All reportable events must be simultaneously reported to all national competent authorities (NCAs) where the PS has commenced. A list of contact points within the NCAs is available on the European Commission\u2019s webpage, aiding in streamlined communication and reporting.<\/span><\/p>\n<\/div><\/div>\n

<\/p>\n

\n

\t\t\t\t\"FDA<\/span>\n\t\t\t<\/div>\n

\n
\n

<\/span>Initiation of Post-Market Surveillance<\/span><\/h2>\n

A PS is deemed to have commenced in a member state (MS) when the sponsor receives authorization to start the study in that MS as per the provisions of the In Vitro Diagnostic Regulation (IVDR). Some MSs may also require reporting to their Ethics Committees.<\/span><\/p>\n

Critical timelines are set for reporting events that present an imminent risk of serious injury, or serious illness. Such events must be reported immediately, but no later than 2 calendar days after the sponsor becomes aware of them. This rapid response is crucial for preventing further harm and addressing significant public health threats.<\/span><\/p>\n

For other reportable events or updates, the reporting must occur immediately but not later than 7 calendar days after awareness. This ensures timely updates on evolving situations or new findings that could impact patient safety.<\/span><\/p>\n

The periodicity and modalities of reporting may vary based on the study\u2019s design and the pathology studied. This allows for flexibility in cases where a high frequency of serious adverse events (SAEs) is expected. This tailored approach ensures that reporting protocols are adapted to the specific risks and needs of the study.<\/span><\/p>\n<\/div><\/div>\n

<\/p>\n

\n
\n

<\/span>Investigator Reporting to Sponsor<\/span><\/h2>\n

The sponsor should also maintain a system to ensure that investigators report all defined reportable events within 3 calendar days of becoming aware of them. This system is vitally important for capturing and escalating critical information quickly and efficiently.<\/span><\/p>\n<\/div><\/div>\n

<\/p>\n

\n
\n

<\/span>Causality Assessment Framework<\/span><\/h2>\n

In accordance with the applicable regulatory requirements, every SAE must be assessed to establish a causal relationship with the use of the in vitro diagnostic (IVD) medical device, the comparator, or the study procedure. This assessment relies on clinical judgment and a review of all relevant documents, such as the Investigator\u2019s Brochure and the Risk Analysis Report.<\/span><\/p>\n<\/div><\/div>\n

<\/p>\n

\n
\n

<\/span>Levels of Causality<\/span><\/h2>\n

As explained by the MDCG, SAEs are categorized into four causality levels:<\/span><\/p>\n